SCALANCE CLP EEC 2GB Removable data storage medium with painted PCBs for easy replacement of the devices in case of fault or failure for storing configuration data; can be used in SCALANCE products with CLP slot: SCALANCE W1788.
SCALANCE CLP 32GB removable data storage medium for simple device replacement in case of fault, for recording configuration data or as memory expansion, can be used in the following products with CLP slot: SCALANCE LPE, SIMATIC Cloud Connect S7, SCALANCE, e.g. SCALANCE W700
SCALANCE CLP 2GB removable data storage medium for simple device replacement in case of fault, for recording configuration data, can be used in the following products with CLP slot: SCALANCE, e.g. SCALANCE W1700 SIMATIC Cloud Connect S7,
FC FO Termination Kit; for FC LC plug; Assembly case for on-site assembly of FC LC connectors to FC FOC cables.
C-plug, removable data storage medium For simple device replacement in case of fault, for recording configuration or engineering and application data, can be used in the following SIMATIC NET products with C-plug slot: SCALANCE XC-200, XP-200, XM-400, XR-500, M-800, W-700, SC-600 and S615.
SINEMA RC client V3 for 1 installation software, documentation on DVD, license key for server; 3 languages (de, en, zh-CHS), Windows 10 Pro, Windows Server 2008, 2012 R2, 2016, 2019 (64-bit).
SIMATIC NET HARDNET-IE S7 V17 SP1 SW f. S7-, open communication: OPC, PG/OP communication, configuration software; up to 120 connections; Floating License Runtime software, Software and electr. manual on DVD; license key on USB flash drive; class A; 2 languages (de, en); for Windows® 10 Professional
SIMATIC NET HARDNET-IE S7 V16 SW for S7-, open communication; OPC, PG/OP communication, Configuration software; up to 120 connections; Floating License Runtime software, software and electr. manual License key for download; Class A; 2 languages (de, en); for Windows 7 SP1 Prof./Ent./Ult. (64 bit);
SIMATIC NET HARDNET-IE S7 V16 SW for S7-, open communication,: OPC, PG/OP communication, Configuration software; up to 120 connections; Floating License Runtime software, software and electr. manual on DVD; License key on USB stick; Class A; 2 languages (de, en); for Windows 7 SP1 Prof./Ent./Ult. (6
Industrial Ethernet S7-1613 Software Update Service for 1 year with automatic Extension requirement: Current software version.
Industrial Ethernet S7-1613 Upgrade for V6.0, V6.1, V6.2 and Edition 2005 SW for S7, S5-comp. communic., OPC, PG/OP communication, NCM PC, up to 120 connections Single License for 1 installation of runtime software, software and electr. manual on CD-ROM, License key on USB stick, Class A 2 languages
HARDNET-IE S7 REDCONNECT V17 SP1 incl. S7 OPC Server, S7-1613 V12 software for fail-safe S7 communication: floating license R-SW, software + electronic manual; license key for download; class A, 2 languages (de, en) for Windows® 10 Professional/Enterprise (64 bit) version 1909, 2004, 20H2; Windows®
Powerpack HARDNET-IE S7-REDCONNECT V17 SP1; for extension HARDNET-IE S7 V17; to HARDNET-IE S7 REDCONNECT V17; Floating License; License key on USB flash drive class A; 2 languages (de, en), for Windows® 10 Professional/Enterprise (64 bit) version 1909, 2004, 20H2; Windows® Server 2016 (Standard Edit
HARDNET-IE S7 REDCONNECT V17 SP1 including OPC server and HARDNET IE-S7 software for fail-safe S7 communication; floating license; R-SW, software + electrical manual on DVD, license key on USB flash drive, class A 2 languages (de, en); for Windows® 10 Professional/Enterprise (64 bit) version 1909, 2
Motor Cable Sh To Lxm, M23, 1,5Mm2, Ul,
Frequency converterFC-301P15KT4E66H1XGX1OXSXXXXAXBXCXXXXDXVLT® AutomationDrive FC-301(P15K) 15 KW / 20 HP, Three phase380 - 480 VAC, (E66) IP66 / NEMA 4X(H1) RFI Class A1/B (C1)No brake chopperGraphical Loc. Cont. PanelNot coated PCB, Mains DisconnectLatest release std. SW.Frame: B1No C1 option, No
MINI MCR-EX-SD-16-50-LFD - Ex i-Solenoid driver for controlling Ex i solenoid valves in the Ex area. no-load voltage: 16 V DC, current limitation: 50 mA, Standard configuration, Line fault detection, Safety Integrity Level (SIL, IEC 61508): 3, Screw connection
Dilinizi seçin
No account yet?